Someone asked me awhile ago why I picked this color scheme? When I saw this template design among those available to us at blogger I liked that it reminded me of the sepia diazo prints I used to make in the past (back when dinosaurs roamed the earth and we used technical pencils/pens to draw).
We used to have to provide a set of sepia prints with our equipment and design submittals when I worked for a theater rigging contractor years ago. These sepia diazo prints permitted altering the document without changing the the original vellum.
I've always liked the way sepia drawings looked when compared with "blueprints". I've seen a few blog templates lately though that have caused me to think about a change...but then I get sepia and go to bed.
Welcome to Steve Stafford's Blog ~ Revit OpEd = OPinion EDitorial ~ My view of things Revit, both real and imagined.
Friday, October 17, 2008
Thursday, October 16, 2008
Wish - Dimension Enhancement
One more wish that I hear very often, place a dimension across multiple elements by sketching a "line". Pick two points to define all elements that should be included in a dimension string. Further to that it would be good if you could sketch a multi-segment "path" as well.
I could wait till Monday...
I could wait till Monday...
Labels:
Dimensions,
Wishlist
Wednesday, October 15, 2008
Implementation by Accident
Don't try THIS at home!!

When a friend sent this image to me I thought of what Phil Read said at Autodesk University in one of his sessions a couple years ago. He said (paraphrasing), "You can't implement Revit accidentally". He was emphasing that implementation is a deliberate activity that requires planning. If you don't then in a way you are doing what this guy is doing...hoping that his supports hold...good luck!!
(I don't know where the photo originally came from but thanks!)

When a friend sent this image to me I thought of what Phil Read said at Autodesk University in one of his sessions a couple years ago. He said (paraphrasing), "You can't implement Revit accidentally". He was emphasing that implementation is a deliberate activity that requires planning. If you don't then in a way you are doing what this guy is doing...hoping that his supports hold...good luck!!
(I don't know where the photo originally came from but thanks!)
Tuesday, October 14, 2008
Dept. of Reviteristics - One Family at a Time
Eric Stewart with Design Development Architects mentioned this to me the other day and I thought it qualified as a "Reviteristic".
When you use the File menu > Load from Library > Load Family you get to load as many families as you can select in a single folder.
When you use one of the various tools to place a component and then choose to Load a new family you only get to load ONE. Eric wonders why? I wonder why? Seems a bit arbitrary to limit us to just one selection in this mode. Using the component placement tools doesn't seem to warrant the limitation.
I say off with the "shackles"!!
When you use the File menu > Load from Library > Load Family you get to load as many families as you can select in a single folder.
When you use one of the various tools to place a component and then choose to Load a new family you only get to load ONE. Eric wonders why? I wonder why? Seems a bit arbitrary to limit us to just one selection in this mode. Using the component placement tools doesn't seem to warrant the limitation.
I say off with the "shackles"!!
Labels:
Families,
Reviteristics
Monday, October 13, 2008
Revit Structure - Wishlist - More Connection Types
We have Moment and Cantilever now.
We need...
Stiffener - Plate Steel welded between flanges
Braced Connection - structure between top flange and bottom flange of another beam
Drag - Beam that connects into another building frame and additional members extend bracing into the adjacent structure.
I suspect that one reason these other options don't exist is that external analysis tools either ignore these connect subtleties or deal with them differently enough that they've held off providing them. This is likely a "documentation" versus "engineering" situation...just a guess on my part.
We need...
Stiffener - Plate Steel welded between flanges
Braced Connection - structure between top flange and bottom flange of another beam
Drag - Beam that connects into another building frame and additional members extend bracing into the adjacent structure.
I suspect that one reason these other options don't exist is that external analysis tools either ignore these connect subtleties or deal with them differently enough that they've held off providing them. This is likely a "documentation" versus "engineering" situation...just a guess on my part.
Sunday, October 12, 2008
Dept. of Reviteristics - The Solution is Delete!!
Whenever you get a warning message or use Review Warnings have you noticed that the solution Revit seems to think is the correct choice for practically every situation is to DELETE the offending element. It is sort of an "off with his head" reaction isn't it?? Is your wall giving you problems...DELETE IT! That's what I do and I feel much better! It is the "duct tape" solution in Revit...101 uses!
I think it would be wonderful if...since Revit caught a problem in the first place...the warnings were more meaningful, in "plain English" and offered us some more useful possibilities in addition to or other than DELETE!
Am I unanimous in this?
I think it would be wonderful if...since Revit caught a problem in the first place...the warnings were more meaningful, in "plain English" and offered us some more useful possibilities in addition to or other than DELETE!
Am I unanimous in this?
Saturday, October 11, 2008
Investment Strategy - Beer Drinkers 401Keg Plan
Assume you purchased $1000.00 in stock from one of these companies just one year ago. The value of your investment would track like this:
Nortel - Now worth $49.00
Enron - Now worth $16.50
WorldCom - Now worth <$5.00
Delta Air Lines - Now worth 49.00
United Airlines - Now worth zero
However, IF you used the same $1000.00 to buy beer instead, assuming aluminum cans, one year ago, consumed all the beer, then recycled the cans you would have +/-$214.00.
Based on the above, the logical conclusion is to drink heavily AND recycle.
This was passed along to me by Ed, Thanks! I don't know who dreamt this up first but it might be a winning strategy as long as the fact that your investment is still a "loser" does not bring you down?
Disclaimer: No, I haven't checked the facts in this claim and even if I had you couldn't count on my math skills anyway. Your return on investment may very depending on the beer you drink. My recommendation...Bass

Cheers Mate!
Nortel - Now worth $49.00
Enron - Now worth $16.50
WorldCom - Now worth <$5.00
Delta Air Lines - Now worth 49.00
United Airlines - Now worth zero
However, IF you used the same $1000.00 to buy beer instead, assuming aluminum cans, one year ago, consumed all the beer, then recycled the cans you would have +/-$214.00.
Based on the above, the logical conclusion is to drink heavily AND recycle.
This was passed along to me by Ed, Thanks! I don't know who dreamt this up first but it might be a winning strategy as long as the fact that your investment is still a "loser" does not bring you down?
Disclaimer: No, I haven't checked the facts in this claim and even if I had you couldn't count on my math skills anyway. Your return on investment may very depending on the beer you drink. My recommendation...Bass

Cheers Mate!
STC - Spot Elevation - Answer
As Afaq says in his comment, a color fill can interfere with placing a Spot Dimension. The other thing that can interfere is Model Graphics Style: Wireframe. A Spot Dimension can't "see" a surface if you are using Wireframe. It won't mind having a color fill or using wireframe after you place the Spot Dimension but you won't be able to place one while either condition exists.
Friday, October 10, 2008
STC - Spot Dimension > Spot Elevation Won't Work
"Stump the Chump...again"
Monica wants to place a Spot Elevation in a plan view. Revit just offers her the "nope you can't" symbol (circle with the line through it). What could be wrong?? Did Monica make Revit mad? She did notice when she put the cursor above an edge it started working however...is that a clue?
Answer tomorrow AM. Post your answer in a comment. Answers/Comments, if any, will be posted in the morning too. (This is probably too easy....)
Monica wants to place a Spot Elevation in a plan view. Revit just offers her the "nope you can't" symbol (circle with the line through it). What could be wrong?? Did Monica make Revit mad? She did notice when she put the cursor above an edge it started working however...is that a clue?
Answer tomorrow AM. Post your answer in a comment. Answers/Comments, if any, will be posted in the morning too. (This is probably too easy....)
Willie Nelson is attending Autodesk University??
When I saw this image on the AUGI home page my first thought was my blog title!

I believe it is really Shaan Hurley's image but it did make me think of Willie first!
Nope, nothing to do with Revit other than there will be Revit classes at AU!
Oh by the way...read the rest of that image! Your last chance to book your spot at AU for the early bird rate is fast approaching.
Per the comment it is Steve Jacobsen, not Shaan.

I believe it is really Shaan Hurley's image but it did make me think of Willie first!
Nope, nothing to do with Revit other than there will be Revit classes at AU!
Oh by the way...read the rest of that image! Your last chance to book your spot at AU for the early bird rate is fast approaching.
Per the comment it is Steve Jacobsen, not Shaan.
Grids That Don't Show Up
Revit will not display Grids that are not perpendicular to the view cut plane. Revit developers chose this because they preferred not to convey ambiguity with important datum elements.

A way to work around this involves a generic model family that contains simple lines in plan to provide something to locate properly in a view. It then uses a symbolic line drawn in the Front Elevation to act as a "Grid Line". He places this family in the project at the intersection of a grid and the element that is parallel to the intended view. The line in the Front View of the family then appears in the elevation or section view.

I used a similar approach in the past to create match lines for a project and to display "3D" grids. When I watched the video I noticed that he didn't take advantage of the Reference Planes IsReference parameters and Instance Parameters. Probably just a matter of keeping the video length to a minimum. Doing so however would make the grid more easily adjustable in the view by using grips instead of setting their length via the properties dialog.
The tricky part of getting the grips is that you don't want to dimension to the Reference Level in the family. You need to use the Reference Plane that is hiding beneath the Level. When you do this then the grips will appear at the ends of the line.

The last part of the puzzle is a tag family for the bubble and grid number. In David's example he put the circle in the grid family and tagged using just the Mark parameter. In my version I've put the circle in the tag too so I don't have to deal with sizing it for the "correct" scale since it could be visible in multiple views assigned to different scales.
I'd prefer to be able to build and nest the annotation for the bubble and mark but in the infinite wisdom of the developers they won't let us place a symbol family in an elevation view within the family editor. Not fair!
I've posted an example project file HERE (640 kb).
(Edit 11/21/2016) Move the following original text from the first paragraph to here because years have gone by and only the fact that David did something in the past for this situation remains available. My post was inspired by his cleverness originally. First paragraph originally included the following sentence.
David Fano posted a lengthy video explaining how he works around this limitation (update: access to the video seems to have been removed since).

A way to work around this involves a generic model family that contains simple lines in plan to provide something to locate properly in a view. It then uses a symbolic line drawn in the Front Elevation to act as a "Grid Line". He places this family in the project at the intersection of a grid and the element that is parallel to the intended view. The line in the Front View of the family then appears in the elevation or section view.

I used a similar approach in the past to create match lines for a project and to display "3D" grids. When I watched the video I noticed that he didn't take advantage of the Reference Planes IsReference parameters and Instance Parameters. Probably just a matter of keeping the video length to a minimum. Doing so however would make the grid more easily adjustable in the view by using grips instead of setting their length via the properties dialog.
The tricky part of getting the grips is that you don't want to dimension to the Reference Level in the family. You need to use the Reference Plane that is hiding beneath the Level. When you do this then the grips will appear at the ends of the line.
The last part of the puzzle is a tag family for the bubble and grid number. In David's example he put the circle in the grid family and tagged using just the Mark parameter. In my version I've put the circle in the tag too so I don't have to deal with sizing it for the "correct" scale since it could be visible in multiple views assigned to different scales.
I'd prefer to be able to build and nest the annotation for the bubble and mark but in the infinite wisdom of the developers they won't let us place a symbol family in an elevation view within the family editor. Not fair!
I've posted an example project file HERE (640 kb).
(Edit 11/21/2016) Move the following original text from the first paragraph to here because years have gone by and only the fact that David did something in the past for this situation remains available. My post was inspired by his cleverness originally. First paragraph originally included the following sentence.
David Fano posted a lengthy video explaining how he works around this limitation (update: access to the video seems to have been removed since).
Thursday, October 09, 2008
Revit MEP - Rehost - Multiple Items
Once upon a time, with the earliest releases of Revit MEP, a deleted host meant not only some rework but lost work as well because those elements were deleted too. So imagine putting in a lot of receptacles or light fixtures and then the architect deleted a ceiling to redesign it. The next time you load their project file you'd find a bunch of stuff missing. Not good...they fixed that! Good thing!
Now when you place equipment, fixtures and devices on a host they just become disassociated with the work plane of their previous host. The elements stay connected to their circuits and no lost work. I'm not saying there isn't rework involved but the stuff you took the time to do didn't just vanish into thin air.
When these elements get disassociated you can select them and choose the REHOST button on the Options Bar.

What some miss is that you can use this tool for multiple elements, say several light fixtures at once. As long as there is a valid host "under" them you should be good to go!
A related issue is, "Gosh, I wonder what the elevation of that ceiling is...before I go nuts sketching duct work and piping?" We'll some will quickly grab their Section tool and sketch a section view to find out. That's good, they've finally gotten comfortable with creating views to explore the model as much as to put on paper. However the Spot Dimension > Spot Elevation tool is a bit handier perhaps?
As long as the view is using something other than wire frame you can place a Spot Elevation to display the elevations of the ceilings. There is an example in the first image above. We can't just tag the ceilings in a linked model so this approach is next best.
Now when you place equipment, fixtures and devices on a host they just become disassociated with the work plane of their previous host. The elements stay connected to their circuits and no lost work. I'm not saying there isn't rework involved but the stuff you took the time to do didn't just vanish into thin air.
When these elements get disassociated you can select them and choose the REHOST button on the Options Bar.

What some miss is that you can use this tool for multiple elements, say several light fixtures at once. As long as there is a valid host "under" them you should be good to go!
A related issue is, "Gosh, I wonder what the elevation of that ceiling is...before I go nuts sketching duct work and piping?" We'll some will quickly grab their Section tool and sketch a section view to find out. That's good, they've finally gotten comfortable with creating views to explore the model as much as to put on paper. However the Spot Dimension > Spot Elevation tool is a bit handier perhaps?
As long as the view is using something other than wire frame you can place a Spot Elevation to display the elevations of the ceilings. There is an example in the first image above. We can't just tag the ceilings in a linked model so this approach is next best.Wednesday, October 08, 2008
Dept. of Reviteristics - Revit MEP - That Pesky Options Bar
When you enter a duct size or offset (elevation) on the Options Bar you may have been bitten by the "old scroll wheel automatico-resizer-syndrome"?? Ouch...you picked a 12" high duct and suddenly you find your height is 48" just because you moved your mouse back over the drawing window and used that middle button/scroll wheel to zoom in or out.

Trouble is the "focus" of Revit is still in that field on the Options Bar. The TAB key, doesn't help. Pressing Enter doesn't help... Nothing seems to...
Well here's what I do, I click on one of the Scroll Bar's buttons to move the focus back into the drawing window. This allows me to move the focus back into the Drawing Window without actually clicking in the Drawing Window, which would place a first point instead of letting me zoom in/out.

Edit: Comment by "Mr. Jackson" suggests his technique: Use the middle button to "pan" for a second. I think is a better solution too!

Trouble is the "focus" of Revit is still in that field on the Options Bar. The TAB key, doesn't help. Pressing Enter doesn't help... Nothing seems to...
Well here's what I do, I click on one of the Scroll Bar's buttons to move the focus back into the drawing window. This allows me to move the focus back into the Drawing Window without actually clicking in the Drawing Window, which would place a first point instead of letting me zoom in/out.

Edit: Comment by "Mr. Jackson" suggests his technique: Use the middle button to "pan" for a second. I think is a better solution too!
Tuesday, October 07, 2008
Shameless Plug - Design West Engineering - Architect's Corner
I had the pleasure of working with Design West Engineering nearly two years ago when they were getting serious about Revit MEP. They had a "can do", "will do" attitude that is essential to being successful with a challenging transition like moving to Revit MEP.
Since then...to steal a phrase my friends back in Atlanta used all the time...they've been "kickin' butt and takin' names". This is polite company (my mom reads this blog now and then, since I don't call her enough) so mentally swap out butt for another term and you've got the essence of the message. 8-)
The other day their Revit Project Manager (Joel Londenberg) shared a link (in a post at AUGI) to a document they've posted on a special page at their company web site called Architect's Corner. They've shared a number of articles that are intended to help their clients work with them as well as information they think might be useful in general. For example one is titled, "How to Swap Models".
Joel (Londenberg) and Jarrod Baumann will be presenting Revit MEP classes at AU this year. If you are attending take another look at your schedule to see if you can catch them in action. Their classes are:
ME318-2 Capturing Design Intent: Building Revit MEP Content that Assists your Engineering Tasks (Joel's class)
ME500-1 From Contract to Construction Documents with Revit MEP (Jarrod's class)
Since then...to steal a phrase my friends back in Atlanta used all the time...they've been "kickin' butt and takin' names". This is polite company (my mom reads this blog now and then, since I don't call her enough) so mentally swap out butt for another term and you've got the essence of the message. 8-)
The other day their Revit Project Manager (Joel Londenberg) shared a link (in a post at AUGI) to a document they've posted on a special page at their company web site called Architect's Corner. They've shared a number of articles that are intended to help their clients work with them as well as information they think might be useful in general. For example one is titled, "How to Swap Models".
Joel (Londenberg) and Jarrod Baumann will be presenting Revit MEP classes at AU this year. If you are attending take another look at your schedule to see if you can catch them in action. Their classes are:
ME318-2 Capturing Design Intent: Building Revit MEP Content that Assists your Engineering Tasks (Joel's class)
ME500-1 From Contract to Construction Documents with Revit MEP (Jarrod's class)
Monday, October 06, 2008
Survey Results - Revit Sweet
Thank to those of you who took time to vote in my quiet little polls! I appreciate the votes and I'll take them to Autodesk with the hope that they will consider it more seriously.
The results of the surveys I posted are: (poll was open to voting for 30 days)
Want a Revit "Sweet"? (156 votes)
115 - Want a Revit Sweet bundle/combo (73%)
24 - Want just two out of three versions (15%)
17 - Only need or want one version of Revit (10%)
Willing to pay how much? (110 votes)
1 - 15k full price basically (0%)
25 - 9.5 k (price of two versions) (22%)
13 - 7.5k (a bit less than two versions) (11%)
71 - 5K plus higher subscription rate (price of one version but willing to pay higher "freight" per month for the additional features) (64%)
Just to clarify it was my intention that this poll reflect the delivery of a "All in One" product, all Revit tools and features combined into one product, one install, one product code. Not the delivery of three separate products for a special price though nobody would object to special pricing for purchasing all three versions at a time. The ideal situation is simpler price, simpler installation, simpler management...one product, one install...all the features.
Background: There are between 300 and 600 readers of this blog visitors per day during the week and it drops to between 100 to 200 on the weekend. I assume most are repeat visitors so this means that roughly a quarter of the readership chose to vote.
My conclusion? A majority of users would like to have Revit "Sweet" and are willing to pay more through their subscription rate to get it. I wasn't surprised by the results for wanting Revit "Sweet" but was a little surprised by the willingness to pay more for subscription as opposed to the 3 for 2 pricing approach. I suppose the assumption is that they'd pay less via subscription somehow.
I hope that Autodesk does some measuring of the market themselves and finds this approach to the delivery of Revit and its toolset to be consistent with my results! They couldn't deliver Revit "Sweet" fast enough for me and most of the clients I visit.
The results of the surveys I posted are: (poll was open to voting for 30 days)
Want a Revit "Sweet"? (156 votes)
115 - Want a Revit Sweet bundle/combo (73%)
24 - Want just two out of three versions (15%)
17 - Only need or want one version of Revit (10%)
Willing to pay how much? (110 votes)
1 - 15k full price basically (0%)
25 - 9.5 k (price of two versions) (22%)
13 - 7.5k (a bit less than two versions) (11%)
71 - 5K plus higher subscription rate (price of one version but willing to pay higher "freight" per month for the additional features) (64%)
Just to clarify it was my intention that this poll reflect the delivery of a "All in One" product, all Revit tools and features combined into one product, one install, one product code. Not the delivery of three separate products for a special price though nobody would object to special pricing for purchasing all three versions at a time. The ideal situation is simpler price, simpler installation, simpler management...one product, one install...all the features.
Background: There are between 300 and 600 readers of this blog visitors per day during the week and it drops to between 100 to 200 on the weekend. I assume most are repeat visitors so this means that roughly a quarter of the readership chose to vote.
My conclusion? A majority of users would like to have Revit "Sweet" and are willing to pay more through their subscription rate to get it. I wasn't surprised by the results for wanting Revit "Sweet" but was a little surprised by the willingness to pay more for subscription as opposed to the 3 for 2 pricing approach. I suppose the assumption is that they'd pay less via subscription somehow.
I hope that Autodesk does some measuring of the market themselves and finds this approach to the delivery of Revit and its toolset to be consistent with my results! They couldn't deliver Revit "Sweet" fast enough for me and most of the clients I visit.
Labels:
Results,
Survey Data
Room Number at Both Ends of a Schedule
This is something I posted a long long time ago at the Zoogdesign forums and then was merged into the AUGI forums, about a door schedule however. A few releases later a better way showed up unannounced in the schedule features though it isn't obvious.
This involves creating a calculated value that we tell Revit to be "equal" to the other parameter we want to duplicate. Here's the calculated value dialog.

This is the resulting schedule based on my conceptual design for my special client.
This schedule includes additional parameters for a room name abbreviation and a client provided program area. I compare the actual area against "theirs" and get the difference. I used a shared parameter for the abbreviation so I can tag the "little" rooms with that instead. I just put two views using either in the image.
This is what the calculated parameter looks like for the difference calculation.
This involves creating a calculated value that we tell Revit to be "equal" to the other parameter we want to duplicate. Here's the calculated value dialog.

This is the resulting schedule based on my conceptual design for my special client.
This schedule includes additional parameters for a room name abbreviation and a client provided program area. I compare the actual area against "theirs" and get the difference. I used a shared parameter for the abbreviation so I can tag the "little" rooms with that instead. I just put two views using either in the image.This is what the calculated parameter looks like for the difference calculation.
Sunday, October 05, 2008
OK and APPLY
Quick Tip: When you see both an OK button and and APPLY button in a dialog...like Visibility/Graphics Overrides...
The APPLY button "applies" the changes you made but does not close the dialog.
The OK button "applies" the change AND closes the dialog.
You do not have to click Apply AND then OK. If you are done making changes click OK. If you want to see your changes first, click APPLY.
Keep in mind if you click CANCEL after using APPLY Revit does not commit any of the changes you made. The OK button commits changes to the database.
I mention this because I see seasoned and new users doing this all the time.
The APPLY button "applies" the changes you made but does not close the dialog.
The OK button "applies" the change AND closes the dialog.
You do not have to click Apply AND then OK. If you are done making changes click OK. If you want to see your changes first, click APPLY.
Keep in mind if you click CANCEL after using APPLY Revit does not commit any of the changes you made. The OK button commits changes to the database.
I mention this because I see seasoned and new users doing this all the time.
Saturday, October 04, 2008
HVAC Load Calculation Extension
There have been other posts about this extension but I figure I'll mention it again..but late. When Autodesk purchased Carmel Software (January 2008) they rebranded it and released it as a subscription benefit. Time for a pretty picture!
What it is:
The HVAC Load Calculation Extension by Autodesk, Inc. is a commercial and industrial HVAC (Heating, Ventilation, and Air Conditioning) load calculation software package whose calculations are based upon the ASHRAE 2005 Fundamentals radiant time series (RTS) method.
It's purpose:
This tool will provide you with total cooling and heating loads for a building so that you may properly specify the correct size HVAC equipment (whether it is a packaged rooftop unit or a boiler). This program is geared specifically toward the HVAC engineer, architect, design/build mechanical contractor, and building maintenance supervisor.
Some key features:
Input HVAC system characteristics such as supply cooling and heating temperatures, ventilation rates, fan characteristics, cooling and heating setpoints, duct sizing, and safety factors
Input HVAC area (room) characteristics such as wall, window, roof, door, skylight, and partition areas. In addition, there are inputs for # of people, electrical appliances, infiltration, lighting, miscellaneous, exhaust, and plenum loads
Weather data from over 800 cities throughout the world
A complete u-value database for common wall, roof, window, floor, and door types
A complete appliance list for determining internal electrical equipment load contributions
Many reports including summary, detailed, psychrometric, wall/window breakdown, 24-hour load breakdown, and graphical reports
A feature that allows the user to export all inputs and outputs to custom Microsoft Word and Excel documents
Equipment selection
Support for both English (IP) and Metric (SI) units
I've noticed a couple traces of Carmel still in the product the other day as pictured here.

The information provided here can be found in the Help documentation for this software. It is provided as a compliment to Revit and AutoCAD MEP software. Most notable is that you can export TO GBXML format from either product, then Import into this extension and THEN export BACK to them.
Check it out!
What it is:The HVAC Load Calculation Extension by Autodesk, Inc. is a commercial and industrial HVAC (Heating, Ventilation, and Air Conditioning) load calculation software package whose calculations are based upon the ASHRAE 2005 Fundamentals radiant time series (RTS) method.
It's purpose:
This tool will provide you with total cooling and heating loads for a building so that you may properly specify the correct size HVAC equipment (whether it is a packaged rooftop unit or a boiler). This program is geared specifically toward the HVAC engineer, architect, design/build mechanical contractor, and building maintenance supervisor.
Some key features:
Input HVAC system characteristics such as supply cooling and heating temperatures, ventilation rates, fan characteristics, cooling and heating setpoints, duct sizing, and safety factors
Input HVAC area (room) characteristics such as wall, window, roof, door, skylight, and partition areas. In addition, there are inputs for # of people, electrical appliances, infiltration, lighting, miscellaneous, exhaust, and plenum loads
Weather data from over 800 cities throughout the world
A complete u-value database for common wall, roof, window, floor, and door types
A complete appliance list for determining internal electrical equipment load contributions
Many reports including summary, detailed, psychrometric, wall/window breakdown, 24-hour load breakdown, and graphical reports
A feature that allows the user to export all inputs and outputs to custom Microsoft Word and Excel documents
Equipment selection
Support for both English (IP) and Metric (SI) units
I've noticed a couple traces of Carmel still in the product the other day as pictured here.

The information provided here can be found in the Help documentation for this software. It is provided as a compliment to Revit and AutoCAD MEP software. Most notable is that you can export TO GBXML format from either product, then Import into this extension and THEN export BACK to them.
Check it out!
Friday, October 03, 2008
Sustainable Forums @ AUGI
I thought I'd mention that in light of the purchase by Autodesk of both Green Building Studio and Ecotect that AUGI has created a new forum group under the AEC banner.

There are three forums for this topic.

I hope that everyone who believes in this issue (or perhaps contests the issue) will find them useful, in particular the "Green Pastures" forum which is intended for broad issue discussion apart from specific software solutions.
Bill Adams has volunteered to be the moderator, thanks Bill!
Enjoy!!

There are three forums for this topic.

I hope that everyone who believes in this issue (or perhaps contests the issue) will find them useful, in particular the "Green Pastures" forum which is intended for broad issue discussion apart from specific software solutions.
Bill Adams has volunteered to be the moderator, thanks Bill!
Enjoy!!
Thursday, October 02, 2008
RTC 2009 - Call for Papers
RTC = Revit Technology Conference (aka The *AU "down-under")
My friend Wesley Benn, his team of experts and the members of the Revit User Group of Sydney (RUGsyd) organize this event each year (fifth year this). I was fortunate enough to attend and present at RTC 2006. I had a lot of fun and I still wear my hat! Events have conspired against me to prevent my return...no loss for them as they've continued to have great sessions and presenters. My loss....
So you like to teach/talk about Revit? Are you looking for an excuse to go to Melbourne, Australia? They are calling all speakers/presenters to offer course submissions for review and acceptance. Here's the pertinent details:

When: June 18-20, 2009
Where: The Sebel Albert Park Hotel, Melbourne, Australia
What do you do now? Download the FORM and follow the instructions!
Deadline for submissions is Friday 31 October 2008. Good luck...but not too much so that you don't knock me out of the running!!
I'll post a link as soon as their site is up and running.
(* AU = Autodesk University)
Oh...you could also just plan to attend!?! You don't HAVE to speak to attend!!
My friend Wesley Benn, his team of experts and the members of the Revit User Group of Sydney (RUGsyd) organize this event each year (fifth year this). I was fortunate enough to attend and present at RTC 2006. I had a lot of fun and I still wear my hat! Events have conspired against me to prevent my return...no loss for them as they've continued to have great sessions and presenters. My loss....
So you like to teach/talk about Revit? Are you looking for an excuse to go to Melbourne, Australia? They are calling all speakers/presenters to offer course submissions for review and acceptance. Here's the pertinent details:

When: June 18-20, 2009
Where: The Sebel Albert Park Hotel, Melbourne, Australia
What do you do now? Download the FORM and follow the instructions!
Deadline for submissions is Friday 31 October 2008. Good luck...but not too much so that you don't knock me out of the running!!
I'll post a link as soon as their site is up and running.
(* AU = Autodesk University)
Oh...you could also just plan to attend!?! You don't HAVE to speak to attend!!
Subscribe to: